Integrations🔗

To set up the integration of Eocortex video surveillance system with the external systems, it is required to go to the /config/svg/ico-tab-automation.png Automation tab in the Eocortex Configurator application, select an individual camera in the camera tree, then, on the opened page, go to the Integrations tab.

../../_images/automation-camera-integration.png

On the tab, it is required to enable the integration with the required system using the /svg/ico-switch-on.png switch, then set up the integration by clicking the /svg/ico-settings.png button.

Paxton Net2

The following tabs are available in the integration settings:

  • General settings;

  • Camera settings.

The General settings tab is used for setting up the connection to the Paxton Net2 ACS server.

../../_images/integration-paxton-general.png

To configure the connection, specify the following parameters:

  • Paxton Net2 server address: IP address or domain name of the Paxton Net2 server

  • SignalR port: Paxton Net2 server connection port

  • REST port: Port for sending REST API requests to the Paxton Net2 server (usually the same as SignalR)

  • Username: Name of the Paxton Net2 account used for connection

  • Password: Password of the Paxton Net2 account used for connection

  • Client ID: Identifier contained in the Paxton Net2 license filename

To test the connection with the provided settings, click the Connect button. The Status section will display the result of the test.

If the connection is successful, further settings should be made on the Camera settings tab.

The Camera settings tab is used for setting up the registration of events from Paxton Net2 objects in Eocortex.

../../_images/integration-paxton-camera.png

To receive events only from certain objects, enable the Receive events from selected objects only: option and check the selected objects.

If the Receive events from selected objects only: option is disabled, Eocortex will register all Paxton Net2 events as related to the selected camera.

Warning

Eocortex registers events for the camera independently of the settings of other cameras, so the same Paxton Net2 object can cause the reaction of the system and create an entry in the Events Log for multiple cameras simultaneously.

Suprema BioStar 2

The following tabs are available in the integration settings:

The General settings tab contains the settings for a network connection to the Suprema BioStar 2 ACS for the whole system.

The following settings are available:

  • Server address: IP address or URL of the Suprema BioStar 2 server. Prefixes, such as http://, are not required to be specified in this field. To enable a secured connection via HTTPS, click the /config/svg/ico-http-connection.svg button.

  • HTTP port: HTTP(S) port of the Suprema BioStar 2 server. Interaction with the ACS utilizes the HTTP and WebSocket protocols, but both protocols use the same port. The WebSocket port can be configured individually in Suprema BioStar 2 settings, but it is not necessary to set it in the integration settings.

  • Username.

  • Password.

When all settings are done, click the Connect button.

Note

The connection test result will be displayed in the Status field.

../../_images/configurator-integration-general-1.png

The Camera settings tab contains settings from which devices the system should receive events for this camera.

Note

By default, all ACS events will be received from all devices.

If the integration is enabled on multiple cameras with the default settings, the events will be duplicated for all enabled cameras.

There are 2 types of Suprema BioStar 2 objects available for configuration:

  • /integration/suprema/img/ico-doors.png Doors. A high-level object that is most often configured with rules in Suprema BioStar 2. Usually the door is connected to a relay and a sensor of other device. Receiving events from specific doors allows to configure the integration more precisely;

  • /integration/suprema/img/ico-devices.png Devices. A lower-level Suprema BioStar 2 object. Setting up to receive events from the device allows configuring the integration more flexibly. For example, if Suprema BioStar 2 is in the deployment phase, the list of doors and their properties will continuously change. When configuring to receive events from the specific door, it will be necessary to change the integration settings each time when something has changed. But when configuring to receive events from a device, when new doors are connected to the device, the integration settings would not need to be changed.

Honeywell Pro-Watch

The connection to the Honeywell's Pro-Watch® comprehensive security platform can be adjusted on the Connection tab.

../../_images/integration-prowatch-connection.png

The connection setup parameters:

  • Pro-Watch server address: the IP address of Honeywell's Pro-Watch® server.

  • SignalR port and REST port are the ports that are used to provide Honeywell's Pro-Watch® API. The default parameters of these ports correspond to the default parameters of Honeywell's Pro-Watch®.

  • Username and Password are the name and Web password of the Honeywell's Pro-Watch® user for whom the access to the Honeywell's Pro-Watch® API service has been set.

After setting up the connection, it is required to test it by clicking on the Connect link. In case of a successful test connection, the list of Honeywell's Pro-Watch® system devices will become available on the Devices tab.

In this list, it is required to mark the devices whose events will be displayed and registered in Eocortex.

ZKBioSecurity

Two tabs are available in the integration settings:

  • General settings;

  • Camera settings.

The General settings tab is used to configure the system-wide connection to ZKBioSecurity.

Note

Setting up the connection to only one ZKBioSecurity server is available per one server system.

The following settings are available:

  • Server address (IP address or URL. Prefixes as http:// are not required to be specified in this field).

    • Use of a secure connection can be set here.

  • Port. Interaction with ZKBioSecurity is performed via HTTP.

  • API access key (Client Secret).

After making the settings, it is required to press the Connect button.

Note

The Status field will show the verification result.

../../_images/settings-config.png

On the Camera settings tab, it is possible to specify the devices whose events are to be received for the given camera.

Note

By default, all the ZKBioSecurity events are received from all devices.

Note

Enabling integration on multiple cameras with the default setting will provide duplication of the events for all enabled cameras.

Three types of ZKBioSecurity objects are available for configuration (full text search is available):

  • Doors /integration/zkbiosecurity/img/ico-doors.png. A high-level object whose rules are usually configured in ZKBioSecurity. Usually, the door is connected to a relay and a sensor of some device. Receiving events from specific doors allows for a more precise integration.

  • Readers /integration/zkbiosecurity/img/ico-readers.png. A high-level object whose rules are usually configured in ZKBioSecurity. Typically, the reader is installed on doors, turnstiles and other access control points. Receiving events from specific readers allows to configure the integration more precisely.

  • Devices /integration/zkbiosecurity/img/ico-devices.png. A lower-level ZKBioSecurity object. Setting up the reception of events from the device permits to configure the integration more flexibly. For example, if multiple doors are connected to the same device and ZKBioSecurity is in the process of being set up, and the doors are being connected and disconnected, the integration settings will have to be changed frequently when setting up the reception of events from the specific doors. In the process of configuring the reception of events from a device, the integration settings do not need to be modified when new doors are being connected to the device.

Note

Changing the names of ZKBioSecurity objects (devices, doors or readers) requires their manual reassignment in the device list every time. Otherwise, the events from the newly renamed object will not be registered.

../../_images/settings-camera.png