Module setup🔗

Warning

Eocortex Neural Networks package must be installed before it will be possible to use neural networks-based features of the module.

To use the module, enable and set up the software motion detector, then enable and set up the module itself.

Launch the Eocortex Configurator, go to the /config/svg/ico-tab-cams.png Cameras tab, select a camera in the list located on the left side of the page, and set up the motion detector on the Motion detector tab on the right side of the page.

Then switch to the Analytics tab and enable the module using the /svg/ico-switch-on.png toggle.

../../_images/module-turn14.png

Clicking the /config/svg/ico-settings.png button opens the module setup window.

In the opened window, it is required to set the detection zones (up to 6) and set the line parameters for each of the zones.

../../_images/queues-configure.png

Detection zones are the zones of the frame bounded by a closed polygon. The zone configuration can be changed by dragging the key points at the corners of the polygon. To add a key point, it is required to double-click the left mouse button on the line; to delete — right-click on the key point.

Alarm event generation: when this option is enabled and in the case of the number of people in the zone exceeding the value set in the Maximum permissible number of people in queue, the Large number of people in the queue alarm event will be generated.

Algorithm sensitivity is the internal value of the module. If the module fails to correctly detect people in the set zone, it is required to increase the sensitivity; if the module counts the foreign objects as people, it is needed to lower the sensitivity.

Averaging of results allows to make counting more resistant to the sharp changes of the quantity of people in the zone. At the same time, the raise of the averaging interval leads to the lag between the actual change of the number of people in the queue and the reflection of this change in the system. The following averaging periods are available: 10, 15, 30 and 60 seconds; it is also possible to disable the usage of averaged results.

Warning

The module will start working only when the settings are applied.